Based in Mumbai — we prepare layout drawings and hydraulic calculations for sprinkler, hydrant, fire alarm and gas suppression systems to NBC, NFPA and FM Global standards.
Vedha Fire is a fire protection design consultancy. We produce layout drawings, hydraulic calculations and coordination documents for fire systems across residential, commercial and industrial buildings.
We work directly with MEP contractors, consultants and developers — taking a project from drawings received to approval-ready submission.
All work is prepared to NBC, NFPA and FM Global standards. We take on projects across India and internationally.
Every drawing we issue is checked against the applicable code, coordinated with the project's architectural and MEP drawings, and sized for the actual site conditions.
We do not produce template drawings. Each layout is prepared from scratch based on the building, the hazard and the authority requirement.
The result is a set of documents that contractors can price, build from and submit for approval.
Three steps from enquiry to delivery.
You send us your architectural or MEP drawings. We review the scope, confirm the applicable standard and come back with a fee and programme.
1We issue a written scope of work. Once confirmed with a purchase order and advance payment, the project starts.
2We produce the layouts, calculations and documentation. Coordination with your team is done as required. Final drawings are issued for approval.
3Fire protection system design for contractors, consultants and developers.
Layout drawings and hydraulic calculations to NBC and NFPA — ensuring required pressure at the most remote sprinkler.
Hydrant riser sizing and landing valve pressure calculation compliant with fire authority requirements.
Pump head calculation, equipment layout and clearance planning for reliable firefighting system operation.
Detailed pressure and flow calculations validating system performance at the hydraulically most remote point.
Detector placement, zoning and cause-effect logic drawings prepared for authority approvals.
Clean agent and inert gas system calculation and nozzle layout for sensitive equipment protection.
Aspirating smoke detection pipe routing and sampling hole calculation for early detection in critical areas.
Watermist nozzle layout and pressure calculation for high-efficiency fire control with minimal water damage.
We are a design-only consultancy. Every project is handled by an experienced fire protection engineer — not passed to a junior or managed through a portal.
Every drawing references the applicable clause. NBC, NFPA and FM Global requirements are checked at layout and calculation stage, not after.
Drawings are sized, coordinated and detailed to the level contractors need on site — not indicative or schematic layouts.
Fire systems are coordinated with architectural and MEP drawings to identify and resolve clashes before construction begins.
You work directly with the engineer on your project. No account managers, no intermediaries, no delays.
All projects are designed in Autodesk Revit - regardless of what format we receive. If your drawings are in AutoCAD, we convert the 2D CAD architecture to a 3D Revit model before starting design. This gives us the coordination accuracy and drawing quality we need to maintain consistent standards across every project. Drawings are issued in the format your team uses.
Design, hydraulic calculations, coordination, authority submission and as-built updates — one point of contact for the complete fire protection scope.
We have delivered fire protection designs across the following building types.
From the contractors, consultants and developers we have worked with.
Vedha Fire delivered our sprinkler and hydrant layouts with excellent coordination. Drawings were construction-ready and passed authority submission without any revisions. Highly recommended.
Fast turnaround and very detailed hydraulic calculations. The pump head report was thorough and the team was responsive throughout. Will continue to use Vedha Fire for all our projects.
The gas suppression design for our server room was exactly what we needed — well-coordinated with the OEM and approval-ready on the first submission. Excellent professional service.
Share your architectural or MEP drawings and we will confirm the scope, applicable standard and fee. Most projects are scoped and priced the same day.
Send Drawings →Answers to what most clients ask before starting a project.
A fire protection consultant designs fire suppression, detection and alarm systems for buildings — ensuring compliance with NBC, NFPA and FM Global standards and producing drawings ready for authority approval.
Sprinkler design includes layout drawings, pipe sizing, remote area hydraulic calculations, coordination with architectural and MEP services, and approval-ready submission documents.
Yes. All design and coordination work is handled remotely — we have delivered projects in Mumbai, Pune, Bangalore, Delhi, Hyderabad and internationally. Location is not a constraint for any project.
We design to NBC (National Building Code of India), NFPA (National Fire Protection Association) and FM Global standards, along with applicable local authority requirements.
Once we receive your drawings and a confirmed purchase order with advance payment, we typically begin within 1–2 working days. Scope and fees are confirmed the same day in most cases.
We work across residential, commercial, industrial, pharmaceutical, data centres, healthcare, hospitality, educational and government infrastructure projects of all sizes.